All 125 volt outlets or receptacles within 2o feet of the inside walls of a pool require gfci protection.
Swimming pool electrical code requirements.
Before summer rolls around now is the perfect time of year to inspect your swimming pools for possible hazards.
Also is to be inspected by a wire inspector.
This web page includes a brief summary of some but not all of the uniform code s requirements relating to swimming pools.
Electrical wiring requirements for swimming pools 2008 national electrical code 2010 residental code of new york state permanently installed swimming pools.
The 2011 revision changed 680 21 c to include 208v by replacing the or with through the requirements have also been relocated to 680 21 from 680 22 subsections in 680 22 renumbered accordingly.
Thanks for your electrical question sue.
Yes this is required by the national electrical code.
The motor is to be grounded the pool is to be grounded in four areas with a 8awg bare wire making a circle around the pool.
Electrical wiring requirements for swimming pools permanently installed swimming pools are those that are constructed in the ground or partially in the ground and all others capable of holding water with a depth greater than 42 inches 1067 mm 1 pool pump receptacle outlet and wiring method a.
Also the water is to be bonded.
Electrical safety is very important especially around pools to ensure the safety of families and other guests.
National electrical code definition are those pools that are constructed or partially in the ground all others pools capable of holding water with a depth greater than 42 inches.
2017 national electrical code sps 316 swimming pool wiring nec article 680 680 5 gfci s may be either circuit breakers or receptacle type.
For added protection of all new pool installations the 2017 nec national electrical code article 680 has been amended.
These rules are current as of the 2017 edition of the nec a coding standard that is updated every three years while changes to the code are gradual it is always a good idea to check on the requirements of the latest edition of the nec.
The nec mandates that overhanging electrical cords must be kept at a safe height from the ground and people s heads for utility power lines that hang over a pool or spa they must have a clearance of 22 5 feet over the water level deck or diving platform communications cables must be at least 10 feet above.
Your local building inspector can let you know what the most current guidelines are for electrical safety around pools and spas.
If a pump motor receptacle is located between.
680 9 overhead wire clearance is min.
10 horizontal from the pool wall.
Cord length for a pump motor is 3 except for storable pools.
All electrical equipment used with storable pools are required to be gfci protected.
If the pool is an above ground and is considered storable then the following codes apply.